- Units are horizontal airflow type and are suitable for mounting on the roof or on the ground
- All units are factory assembled, piped, internally wired and fully charged with R-22 or R407C or R410A refrigerants
- Units are tested in accordance with ARI Standards
- Units are available in following voltages:
- 380-415V/3PH/50 HZ and 380V/3PH/60HZ
- 208-230V/3PH/60 HZ and 460V/3PH/60HZ
- Compressors are fully hermetic type designed for high efficiency provided with standard control and safety devices like HP and LP controls and crank case heater for scroll compressors
- All units are provided with compressor lockout either by locking relays or by high pressure control trip with manual reset switch
- Evaporator blowers are belt driven centrifugal type, forward curve blade design, sized to meet system air flow and static. Backward curved blowers can be given as an option
- Condenser fans are propeller type, direct drive, draw through vertical discharge with fan guard mounted to the panel
- Thermostatic expansion valve/metering device provides precision control for maximized cooling
- Primary control circuit is designated to operate at 240 volts. Control circuit 230 volts can be provided as an option
Optional Features:
- Anti-corrosive coated fins for condenser coils
- Hydrophilic coated fins for evaporator coils
- Copper Fins for Condenser and evaporator coils
- Thermostat provides cooling, staged heating and fan control
- Antifreeze thermostats
- Hour meter
- Voltage monitor
- Phase loss protection
- Fan speed controller
- Temperature , humidity sensors
- Micro Processor control
- Fan Cycling switch
- Compressor alternating switch
- Compressor interlock with blower
- Pump down system
- Over load thermal protection for compressor
- Over load thermal protection for motors
- Volt free contacts for BMS
- Dual and adjustable pressure switches
- 100% fresh air rooftop
- Double skin construction
- Stainless stell tray/hardware
- Fine/bag filter
- PCB
- Backward curved blower
- Units are horizontal airflow type and are suitable for mounting on the roof or on the ground
- All units are factory assembled, piped, internally wired and fully charged with R-22 or R407C or R410A refrigerants
- Units are tested in accordance with ARI Standards
- Units are available in following voltages:
- 380-415V/3PH/50 HZ and 380V/3PH/60HZ
- 208-230V/3PH/60 HZ and 460V/3PH/60HZ
- Compressors are fully hermetic type designed for high efficiency provided with standard control and safety devices like HP and LP controls and crank case heater for scroll compressors
- All units are provided with compressor lockout either by locking relays or by high pressure control trip with manual reset switch
- Evaporator blowers are belt driven centrifugal type, forward curve blade design, sized to meet system air flow and static. Backward curved blowers can be given as an option
- Condenser fans are propeller type, direct drive, draw through vertical discharge with fan guard mounted to the panel
- Thermostatic expansion valve/metering device provides precision control for maximized cooling
- Primary control circuit is designated to operate at 240 volts. Control circuit 230 volts can be provided as an option
Optional Features:
- Anti-corrosive coated fins for condenser coils
- Hydrophilic coated fins for evaporator coils
- Copper Fins for Condenser and evaporator coils
- Thermostat provides cooling, staged heating and fan control
- Antifreeze thermostats
- Hour meter
- Voltage monitor
- Phase loss protection
- Fan speed controller
- Temperature , humidity sensors
- Micro Processor control
- Fan Cycling switch
- Compressor alternating switch
- Compressor interlock with blower
- Pump down system
- Over load thermal protection for compressor
- Over load thermal protection for motors
- Volt free contacts for BMS
- Dual and adjustable pressure switches
- 100% fresh air rooftop
- Double skin construction
- Stainless stell tray/hardware
- Fine/bag filter
- PCB
- Backward curved blower
- Above 25 TR, Condensing Units up to 90 tons are available and can be matched with suitable Air Handling Units
- Units are horizontal airflow type and are suitable for mounting on the roof or on the ground
- All units are factory assembled, piped, internally wired and fully charged with R-22 or R407C or R410A refrigerants
- Units are tested in accordance with ARI Standards
- Units are available in following voltages:
- 380-415V/3PH/50 HZ & 380V/3PH/60HZ
- 208-230V/3PH/60 HZ & 460V/3PH/60HZ
- Compressors are fully hermetic type designed for high efficiency provided with standard control and safety devices like HP & LP controls and crank case heater for scroll compressors
- All units are provided with compressor lockout either by locking relays or by high pressure control trip with manual reset switch
- Evaporator blowers are belt driven centrifugal type, forward curve blade design, sized to meet system air flow and static. Backward curved blowers can be given as an option
- Condenser fans are propeller type, direct drive, draw through vertical discharge with fan guard mounted to the panel
- Thermostatic expansion valve/metering device provides precision control for maximized cooling
- Primary control circuit is designated to operate at 24 volts. Control circuit 230 volts can be provided as an option
Optional Features:
- Anti-corrosive coated fins for condenser coils
- Hydrophilic coated fins for evaporator coils
- Copper Fins for condenser and evaporator coils
- Thermostat: provides cooling, staged heating and fan control
- Antifreeze thermostats
- Hour meter
- Voltage monitor
- Phase loss protection
- Fan speed controller
- Temperature , humidity sensors
- Micro Processor control
- Fan Cycling switch
- Compressor alternating switch
- Compressor interlock with blower
- Pump down system
- Over load thermal protection for compressor
- Over load thermal protection for motors
- Volt free contacts for BMS
- Dual and adjustable pressure switches
- 100% fresh air rooftop
- Double skin construction
- SS tray / hardware
- Fine/bag filter
- PCB
- Backward curved blower
Standard Features:
- The 4AH series Air Handling units are based on Awal’s ADS series. This series features Flexible Modular type construction with 11 basic sizes covering a wide range of air flow from 2890 m3/hr to 45,680 m3/hr
- The combination of width and height dimensions within the basic sizes offers flexibility in sizing the unit to fit into various on-site space requirements
- Fan and Motor assembly is mounted on a common base with suitable vibration isolators to ensure that they are isolated from the main case structure
- The ADS units are offered with double skin panels with 25mm/45mm thickness, fabricated from heavy gauge galvanized steel sheet dully finished with powder coat Fan and Motor assembly is mounted on a common base with suitable vibration Isolators to ensure that they are isolated from the main case structure
- Units are manufactured at an ISO 9001 certified facility center ensuring quality standards for the components used in construction of the units
- Powder coated outer panels are feature of ADS series; however blue skin panels are available as an option
- All components are standard and interchangeable
- Access panels are provided with easily removable fasteners to facilitate easy maintenance
Panels
- Each of the panels is made up of 0.7mm pre-painted sheet and 1.0mm Zinc coated inner panel
- These panels are inserted between Rockwool insulation of uniform density (40 kg/m3) ensures low thermal conductivity and robust construction
- Polyurethane foam can be given as optional
Blower Assembly
- High energy efficient, fans with backward/forward curved blades with DIDW (double inlet double width) construction are available for various static pressure requirements
- The motors are TEFC type with either IP54/IP55 protection and with class F insulation
- Fan and Motor is mounted on a common extruded aluminum channel base, by using anti-vibration isolators
Coils
- Coils are sized and designed by the computerized software selection program and manufactured in our state- of- the- art technology plant and tested as per the test conditions specified by ARI 410 Standards Corrugated plate type fin is die-formed
- Fin collars are full drawn to provide accurate control fin spacing and maximum contact with tubes.
- All coils are leak tested under water at 315 psig air
- Coils can be with copper tubes, copper fins or with Hera site-Epoxy coating
Air control devices
- The dampers are used for air control and minimize the pressure loss as well as to reduce noise
- These mixing boxes are configured with opposed blades and driven by a polycarbonate gear mechanism to ensure smooth operation
Filters
- Air Filtration is of paramount importance and this ensures best quality of IAQ
- Choices of single and multi-stage air filters are available to suit different environmental conditions
- Filters are placed in galvanized frames for easier side removal and effortless maintenance
- Manometer plug ports are provided to fix manometer and check for filter pressure drops
- All filters offered are made to follow ASHRAE and Euro Vent Conventional Standards
Condensate Drain Pan
- Specially designed Drain Pan made of GI dully finished with powder coating material and insulated to prevent condensation
- The drain connection is available for both the sides of the drain pan so that it is easy to connect to the main drains at the site
Optional Features
- Heat recovery wheel
- Horse shoe heat pipe
- Backward curved blower
- Hot water coil
- Electric heater with Air Flow switch
- Electrical Humidifier
- Custom designed unit
- Pre-coated sheet metal
- Stainless steel drain pan, hinges, fasteners and screws
- Special coating for coil
- Copper fins for coil
Standard Features:
- Air Cooled Package chillers have been developed and produced to provide not only the optimum performance, but also to guarantee long and trouble free operations
- Herein lies the reason for the choice of only the highest quality components and design strategies to meet the most important objective such as,
- Efficiency
- Reliability
- Flexibility
- Easy Installation
- Serviceability
- Affordability
- Chillers are designed, manufactured and shipped as a complete package which are run tested at factory before dispatch.
- A wide range of chiller capacities and options available with refrigerant R407C, R410A, R22 both 50 HZ and 60HZ operation.
- Microprocessor based chiller controller effectively manages the operation of chiller at different conditions. The units are completely factory wired with single point power input
- Easy accessible control box, compressor, controls
- Primary control circuit is designed to operate at 24 volts. Control circuit 230 volts can be given as an option
- All the units are provided with compressor lockout either by locking relays or by high pressure control trip with manual reset switch
- All the units are provided with 2.5-3 min time delay for compressor start
- Units are provided with efficient PHE’s or Shell and the tube evaporators with T/S
- Quality Assurance
- All chillers are run tested at factory prior to dispatch
- Produced in ISO9001-2000 listed manufacturing facility
- Designed and rated to the conditions as per ARI standards
- Chillers are made in compact foot print
- Aluminum profile construction is unique feature of Awal Gulf Chiller design
- Sheet metal frame construction can also be provided as optional
Standard Features
- Corrosion free profile construction
- Modular design gives greater flexibility
- Easily accessible system components
- Multiple compressor design, gives control over different load conditions
- Units are fitted with scroll compressor with anti-vibration mounts
- Refrigeration circuit complete with TEX valve, replaceable drier, sight glass etc.
- Compressor and fan motor provide with overload relays for protection
- Cool only model is standard option
- HP/LP switches provided as protection for the system
Optional Features:
- Anti-corrosive coated fins for condenser coils
- Stainless steel heat exchangers for special applications
- Copper fins for condenser
- Phase loss protection
- Fan speed controller
- Fan cycle switch
- Compressor alternating switch
- Compressor interlock with pump(others)
- Pump down system
- Over load thermal protection for compressor
- Over load thermal protection for motors
- Volt free contact for BMS
- Dual and adjustable pressure switches
- Pump down control
- Hot gas bypass for capacity regulation
- Plate heat exchangers as optional can be given for special application
- High point cooler
- Heavy duty dust proof (IP 55) electrical panel available for specific models
- Protective grill can be given for compressor and condenser section as optional
- HP/LP gauges can be provided.